Instruction video requiring clean voice not too "salesy". We are showing the unit on screen being actuated as the voice explains what is happening. Please call 814-746-9986 if you have questions.
his video is a step by step guide to changing the Set Point of a Limeco EZ Nitrogen Loading System.

Pronunciations:

Pronunciations:

PSI - “pee-ess-eye”
FAilSF - “Fail safe”
EZ - “easy”
Limeco - “Lih-mee-co”
IR - “eye-argh”
rELAY - “ree-lay”
rST - argh - ess - tee

4-5 minute estimate. Time is not an issue. Please read at a normal pace. 
2017-02-10 14:46:59 GMT
2017-02-14 09:00:00 (GMT -05:00) Eastern Time (US & Canada) 
Yes (click here to learn more about Voice123's SmartCast)
Closed
20
6
0 direct invitation(s) have been sent by the voice seeker resulting in 0 audition(s) and/or proposal(s) so far.
Voice123 SmartCast is seeking 20 auditions and/or proposals for this project (approx.) Invitations sent by SmartCast have resulted in 20 audition(s) and/or proposal(s) so far.

Project Parameters

The Voice Actor should be located in:
Fixed - USD 200
Training, business presentations, sales, and web sites
Via Internet: Company website
5 MINUTES
English - USA and Canada
Not defined
Middle Age Female OR Middle Age Male OR Senior Female OR Senior Male
• Audio files must be delivered via email
There are no special pre-, post-, or production requirements for this project.
Not defined
The voice seeker is willing to hire either union or non-union talents for this project

Script Details

Yes
N/A 
This video is a step by step guide to changing the Set Point of a Limeco EZ Nitrogen Loading System. It is recommended to have the set and reset points from Step 1 determined prior to changing any settings in the electronics.

For our example today, we will be changing the Limeco EZ system from 125 PSI to 135 PSI.
In a hazardous environment the cover of the controller must remain in place. Programming of the controller can be done through the glass using the infrared buttons or IR Buttons on the top and bottom of the display. The IR buttons are disabled at the factory so if you would like to activate them please contact Liquid Meter Company. For non-hazardous areas you can begin by removing the cover on the blue controller.
Once the cover is removed you will use the gray push buttons on the right hand side of the controller to navigate through menus. At any point the user is unsure of the settings or would like to start the process over, press the Menu button and it will return to the main display. Be advised this will restart the program and any changes will not be saved.

With the controller showing the current system pressure, begin by pressing “F1” one time changing the display to “rELAY”.
Continue by pressing “F3” five times until the controller displays a six digit number with “Set 1” under it.
Use “F1” to select the digit and “F2” to change the value of the digit. In our example for Relay 1, Set 1 we changed 120 PSI to 130 PSI.
Once the desired numbers are entered for Relay 1 Set 1, press “F3” twice until the screen displays a new six digit number with “rST 1” under it.

Continue to use “F1” to select the digit and “F2” to change the value of the digit. In our example for Relay 1, Reset 1 we changed 124 PSI to 134 PSI.
For relay 2, press “F3” five times until the screen displays the next six digit number with “Set 2” under it.

Continue to use “F1” to select the digit and “F2” to change the value of the digit. In our example for Relay 2, Set 2 we changed 130 PSI to 140 PSI.
Once the new numbers are entered for Set 2, press “F3” twice until the screen displays a new six digit number with “rST 2” under it.

Continue to use “F1” to select the digit and “F2” to change the value of the digit. In our example for Relay 2, Reset 2 we changed 126 PSI to 136 PSI.

For relay 3, press “F3” five times until the screen displays the next six digit number with “Set 3” under it.

Use “F1” to select the digit and “F2” to change the value of the digit. In our example for Relay 3, Set 3 we changed 118 PSI to 128 PSI.
Once the new numbers are entered for Set 3, press “F3” twice until the screen displays a new six digit number with “rST 3” under it.

Continue to use “F1” to select the digit and “F2” to change the value of the digit. In our example for Relay 3, Reset 3 we changed 118.1 PSI to 128.1PSI.

For the fourth and final relay, press “F3” five times until the screen displays the next six digit number with “Set 4” under it.

Use “F1” to select the digit and “F2” to change the value of the digit. In our example for Relay 4, Set 4 we changed 132 PSI to 142 PSI.
Once the new numbers are entered for Set 4, press “F3” twice until the screen displays a new six digit number with “rST 4” under it.

Continue to use “F1” to select the digit and “F2” to change the value of the digit. In our example for Relay 4, Reset 4 we changed 131.9 PSI to 141.9 PSI.
To complete the set point change process press the “F3” button one time causing the display to change to “FAilSF”, then press “Menu” to return to normal operation. If these final steps do not happen then the set point information will not be saved in the controller.
Please continue to Step 3 to complete the set point change procedure. 
Please note that you should only use the script or your recording of it for auditioning purposes. The script is property, unless otherwise specified, of the voice seeker and it is protected by international copyright laws.

Voice-Seeker Details

52030
Sign in to display the company name (if applicable)
2008-12-22
34

15


Voice123 Team Comments

Voice123 consultations with this voice seeker regarding this project and/or other projects by this voice seeker, via phone, chat, and/or email.


unchecked This project - phone.

checked Previous projects - phone.


unchecked This project - email or chat.

checked Previous projects - email or chat.



Note: Voice123 strives to establish the legitimacy of all projects posted. However, Voice123 subscribers and users are responsible for confirming information stated by prospective voice seekers, agents and/or clients. Voice123 subscribers and users assume all liability for use of any information found through Voice123, or any of its publications.

This page contains the most important details of this project. If you find the information on this project inaccurate or inappropriate, please let us know by contacting us.

Submit Audition/Proposal on this Project