Catheter Narration

Submit Audition/Proposal on this Project
Rate this Project

Project Main Details

Catheter Narration  
This is a medical animation showing a new catheter design.
2012-07-01 21:00:46 GMT
2012-07-05 20:00:00 (GMT -05:00) Eastern Time (US & Canada) 
Yes (click here to learn more about Voice123's SmartCast)
0 direct invitation(s) have been sent by the voice seeker resulting in 0 audition(s) and/or proposal(s) so far.
Voice123 SmartCast is seeking 50 auditions and/or proposals for this project (approx.) Invitations sent by SmartCast have resulted in 0 audition(s) and/or proposal(s) so far.

Project Parameters

The Voice Actor should be located in:
Student or Non-for-profit student project - USD 100
Training, business presentations, sales, and web sites
272 words
English - British OR English - USA and Canada
A british accent is preferred
Young Adult Female OR Young Adult Male OR Middle Age Female OR Middle Age Male OR Senior Female OR Senior Male
• Audio files must be delivered via email
• Deliver edited and finished voice tracks
The Voice Actor should have at least 2 years of experience in the voice industry.
The voice seeker is willing to hire either union or non-union talents for this project

Script Details

***custom demo required*** 
The ********************************** is a universal therapeutic infusion catheter for localized delivery of agents to the peripheral vasculature. It is a five lumen catheter consisting of a guide wire lumen, an inflation lumen for the proximal and distal occlusion balloons, an inflation lumen for the space occupying balloon, an inflow lumen and an outflow lumen. A fiber optic pressure sensor is incorporated into the inflow lumen to monitor pressure within the treatment chamber. Radiopaque markers are located on both occlusion balloons to define the treatment chamber.

The catheter is advanced over the guide wire into the area to be treated. The proximal and distal occlusion balloons are inflated, trapping blood within the treatment chamber. The blood is evacuated from the treatment chamber by flushing the chamber with saline. The space occupying balloon is inflated to minimize the quantity of therapeutic agent that is required. The saline is removed by flushing the chamber with the therapeutic agent of choice. The space occupying balloon is partially deflated. Additional therapeutic agent is added to the treatment chamber. The space occupying balloon is re-inflated, pressurizing the chamber, allowing the agent to penetrate into the media, circumferentially and longitudinally. The pressure within the chamber is controlled by constant monitoring of the pressure sensor. The space occupying balloon never touches the vessel wall. When the therapy is completed, the space occupying balloon is deflated and the excess agent is evacuated from the chamber to control systemic effect. The occlusion balloons are deflated, reestablishing blood flow. The OPC is reusable and can be repositioned to treat excessively long lesions or multiple lesions.

Thank you for choosing *************************** 
Voice123 Note: Names, links, and contact information have been replaced by "*" symbols. If you have been invited to submit an audition or proposal for this project, you can sign in to see this information in full.
Please note that you should only use the script or your recording of it for auditioning purposes. The script is property, unless otherwise specified, of the voice seeker and it is protected by international copyright laws.

Voice-Seeker Details

Sign in to display the company name (if applicable)


Voice123 Team Comments

Voice123 consultations with this voice seeker regarding this project and/or other projects by this voice seeker, via phone, chat, and/or email.

unchecked This project - phone.

checked Previous projects - phone.

unchecked This project - email or chat.

checked Previous projects - email or chat.

checked Corporate web site for this voice-seeker confirmed by Voice123

Note: Voice123 strives to establish the legitimacy of all projects posted. However, Voice123 subscribers and users are responsible for confirming information stated by prospective voice seekers, agents and/or clients. Voice123 subscribers and users assume all liability for use of any information found through Voice123, or any of its publications.

This page contains the most important details of this project. If you find the information on this project inaccurate or inappropriate, please let us know by contacting us.

Submit Audition/Proposal on this Project